932 research outputs found

    Use of MMG signals for the control of powered orthotic devices: Development of a rectus femoris measurement protocol

    Get PDF
    Copyright © 2009 Rehabilitation Engineering and Assistive Technology Society (RESNA). This is an Author's Accepted Manuscript of an article published in Assistive Technology, 21(1), 1 - 12, 2009, copyright Taylor & Francis, available online at: http://www.tandfonline.com/10.1080/10400430902945678.A test protocol is defined for the purpose of measuring rectus femoris mechanomyographic (MMG) signals. The protocol is specified in terms of the following: measurement equipment, signal processing requirements, human postural requirements, test rig, sensor placement, sensor dermal fixation, and test procedure. Preliminary tests of the statistical nature of rectus femoris MMG signals were performed, and Gaussianity was evaluated by means of a two-sided Kolmogorov-Smirnov test. For all 100 MMG data sets obtained from the testing of two volunteers, the null hypothesis of Gaussianity was rejected at the 1%, 5%, and 10% significance levels. Most skewness values were found to be greater than 0.0, while all kurtosis values were found to be greater than 3.0. A statistical convergence analysis also performed on the same 100 MMG data sets suggested that 25 MMG acquisitions should prove sufficient to statistically characterize rectus femoris MMG. This conclusion is supported by the qualitative characteristics of the mean rectus femoris MMG power spectral densities obtained using 25 averages

    The design and characterization of a 300 channel, optimized full-band millimeter filterbank for science with SuperSpec

    Get PDF
    SuperSpec is an integrated, on-chip spectrometer for millimeter and sub-millimeter astronomy. We report the approach, design optimization, and partial characterization of a 300 channel filterbank covering the 185 to 315 GHz frequency band that targets a resolving power R ~ 310, and fits on a 3.5×5.5 cm chip. SuperSpec uses a lens and broadband antenna to couple radiation into a niobium microstrip that feeds a bank of niobium microstrip half-wave resonators for frequency selectivity. Each half-wave resonator is coupled to the inductor of a titanium nitride lumped-element kinetic inductance detector (LEKID) that detects the incident radiation. The device was designed for use in a demonstration instrument at the Large Millimeter Telescope (LMT)

    Depression, Stressful Life Events, and the Impact of Variation in the Serotonin Transporter: Findings from the National Longitudinal Study of Adolescent to Adult Health (Add Health)

    Get PDF
    BackgroundThe low transcriptionally efficient short-allele of the 5HTTLPR serotonin transporter polymorphism has been implicated to moderate the relationship between the experience of stressful life events (SLEs) and depression. Despite numerous attempts at replicating this observation, results remain inconclusive.MethodsWe examined this relationship in young-adult Non-Hispanic white males and females between the ages of 22 and 26 (n = 4724) participating in the National Longitudinal Study of Adolescent to Adult Health (Add Health) with follow-up information every six years since 1995.ResultsLinear and logistic regression models, corrected for multiple testing, indicated that carriers of one or more of the S-alleles were more sensitive to stress than those with two L-alleles and at a higher risk for depression. This relationship behaved in a dose-response manner such that the risk for depression was greatest among those who reported experiencing higher numbers of SLEs. In post-hoc analyses we were not able to replicate an interaction effect for suicide ideation but did find suggestive evidence that the effects of SLEs and 5HTTLPR on suicide ideation differed for males and females. There were no effects of childhood maltreatment.DiscussionOur results provide partial support for the original hypothesis that 5-HTTLPR genotype interacts with the experience of stressful life events in the etiology of depression during young adulthood. However, even with this large sample, and a carefully constructed a priori analysis plan, the results were still not definitive. For the purposes of replication, characterizing the 5HTTLPR in other large data sets with extensive environmental and depression measures is needed

    Radiation damage in the LHCb vertex locator

    Get PDF
    The LHCb Vertex Locator (VELO) is a silicon strip detector designed to reconstruct charged particle trajectories and vertices produced at the LHCb interaction region. During the first two years of data collection, the 84 VELO sensors have been exposed to a range of fluences up to a maximum value of approximately 45 × 1012 1 MeV neutron equivalent (1 MeV neq). At the operational sensor temperature of approximately −7 °C, the average rate of sensor current increase is 18 μA per fb−1, in excellent agreement with predictions. The silicon effective bandgap has been determined using current versus temperature scan data after irradiation, with an average value of Eg = 1.16±0.03±0.04 eV obtained. The first observation of n+-on-n sensor type inversion at the LHC has been made, occurring at a fluence of around 15 × 1012 of 1 MeV neq. The only n+-on-p sensors in use at the LHC have also been studied. With an initial fluence of approximately 3 × 1012 1 MeV neq, a decrease in the Effective Depletion Voltage (EDV) of around 25 V is observed. Following this initial decrease, the EDV increases at a comparable rate to the type inverted n+-on-n type sensors, with rates of (1.43±0.16) × 10−12 V/ 1 MeV neq and (1.35±0.25) × 10−12 V/ 1 MeV neq measured for n+-on-p and n+-on-n type sensors, respectively. A reduction in the charge collection efficiency due to an unexpected effect involving the second metal layer readout lines is observed

    Negative incentive steering in a policy network

    Get PDF
    In this article the process of developing a policy for the recent comprehensive retrenchment operation in the Dutch university system is analysed from a theoretical point of view on decisionmaking. The article especially addresses the question whether some empirical evidence can be found for the rationalist view of collective decision-making, which states that a process of social communication should eventually lead to a unanimous and rational consensus concerning the selection of the optimal policy.\ud \ud The actual analysis concerns the way a retrenchment policy has been developed in a process of social communication between the most important actors: the Minister of Education and Science and the thirteen Dutch universities. It is assumed that the various communicative linkages between these actors can be interpreted as a policy network in which both governmental and non-governmental actors operate.\ud \ud The article concludes that in the Dutch university policy-network a complicated balance of interdependencies exists and that several sub-networks can be distinguished. It is also concluded that the Minister, while recognizing the interdependencies in the network, was able to use a special kind of (negative) incentive, inducing the universities to act as he wished.\ud \ud This negative incentive steering, however, also persuaded the universities to go to the utmost in their consultation efforts, thus trying to reach the rationalist ideal of collective decision-making. The final conclusion therefore is that the rationalist view of collective decision-making does not appear to be unrealistic. The article ends with a warning against a common mistake made regarding the normative appearance of the rationalist perspective

    Morphino: A nature-inspired tool for the design of shape-changing interfaces

    Get PDF
    The HCI community has a strong and growing interest in shape-changing interfaces (SCIs) that can offer dynamic af- fordance. In this context, there is an increasing need for HCI researchers and designers to form close relationships with dis- ciplines such as robotics and material science in order to be able to truly harness the state-of-the-art in morphing technolo- gies. To help these synergies arise, we present Morphino: a card-based toolkit to inspire shape-changing interface designs. Our cards bring together a collection of morphing mechanisms already established in the multidisciplinary literature and illustrate them through familiar examples from nature. We begin by detailing the design of the cards, based on a review of shape-change in nature; then, report on a series of design sessions conducted to demonstrate their usefulness in generating new ideas and in helping end-users gain a better understanding of the possibilities for shape-changing materials

    Full-Array Noise Performance of Deployment-Grade SuperSpec mm-Wave On-Chip Spectrometers

    Get PDF
    SuperSpec is an on-chip filter bank spectrometer designed for wideband moderate-resolution spectroscopy at millimeter wavelengths, employing TiN kinetic inductance detectors. SuperSpec technology will enable large-format spectroscopic integral field units suitable for high-redshift line intensity mapping and multi-object spectrographs. In previous results, we have demonstrated noise performance in individual detectors suitable for photon noise-limited ground-based observations at excellent mm-wave sites. In these proceedings, we present the noise performance of a full R∼275 spectrometer measured using deployment-ready RF hardware and software. We report typical noise equivalent powers through the full device of ∼3×10⁻¹⁶ W Hz^(−1/2) at expected sky loadings, which are photon noise dominated. Based on these results, we plan to deploy a six-spectrometer demonstration instrument to the Large Millimeter Telescope in early 2020

    Performance of the LHCb vertex locator

    Get PDF
    The Vertex Locator (VELO) is a silicon microstrip detector that surrounds the proton-proton interaction region in the LHCb experiment. The performance of the detector during the first years of its physics operation is reviewed. The system is operated in vacuum, uses a bi-phase CO2 cooling system, and the sensors are moved to 7 mm from the LHC beam for physics data taking. The performance and stability of these characteristic features of the detector are described, and details of the material budget are given. The calibration of the timing and the data processing algorithms that are implemented in FPGAs are described. The system performance is fully characterised. The sensors have a signal to noise ratio of approximately 20 and a best hit resolution of 4 μm is achieved at the optimal track angle. The typical detector occupancy for minimum bias events in standard operating conditions in 2011 is around 0.5%, and the detector has less than 1% of faulty strips. The proximity of the detector to the beam means that the inner regions of the n+-on-n sensors have undergone space-charge sign inversion due to radiation damage. The VELO performance parameters that drive the experiment's physics sensitivity are also given. The track finding efficiency of the VELO is typically above 98% and the modules have been aligned to a precision of 1 μm for translations in the plane transverse to the beam. A primary vertex resolution of 13 μm in the transverse plane and 71 μm along the beam axis is achieved for vertices with 25 tracks. An impact parameter resolution of less than 35 μm is achieved for particles with transverse momentum greater than 1 GeV/c

    Precision luminosity measurements at LHCb

    Get PDF
    Measuring cross-sections at the LHC requires the luminosity to be determined accurately at each centre-of-mass energy √s. In this paper results are reported from the luminosity calibrations carried out at the LHC interaction point 8 with the LHCb detector for √s = 2.76, 7 and 8 TeV (proton-proton collisions) and for √sNN = 5 TeV (proton-lead collisions). Both the "van der Meer scan" and "beam-gas imaging" luminosity calibration methods were employed. It is observed that the beam density profile cannot always be described by a function that is factorizable in the two transverse coordinates. The introduction of a two-dimensional description of the beams improves significantly the consistency of the results. For proton-proton interactions at √s = 8 TeV a relative precision of the luminosity calibration of 1.47% is obtained using van der Meer scans and 1.43% using beam-gas imaging, resulting in a combined precision of 1.12%. Applying the calibration to the full data set determines the luminosity with a precision of 1.16%. This represents the most precise luminosity measurement achieved so far at a bunched-beam hadron collider

    Measuring Organizational Power: Resources and Autonomy of Government Agencies

    Get PDF
    Although power is a major concern of organization theory, little research has focused on the horizontal dimension of power between organizations at relatively equal hierarchical levels. This study attempts to fill that void by operationalizing organizational power for 127 federal government agencies. The derived measure is subjected to tests for internal and external validity by empirically testing one promising theory of agency power.Yeshttps://us.sagepub.com/en-us/nam/manuscript-submission-guideline
    corecore